IntelliLogger™ Enc300 Enclosure Option

Rugged enclosure provides IntelliLogger protection from weather and industrial environments

IL-80 mounted in Enc300 with one additional ILIM-7 Analog Input Module and Cellular Modem
Enc300 Key Features
Medium size enclosure. Can house IntelliLogger plus up to four Expansion Modules
Hardshell ABS construction
IntelliLogger slide-out access for wiring
Dual door closing latches with lock
Silicone gasketed door
Sealing gland fittings for bottom wiring ingress/egress
Surface mounting hanger option
Options for batteries, modems, WiFi, Sensor excitation…

Product Images

IL-80 mounted in Enc300 with BPB-1 BBus Power Booster, PSM-2 Sensor Excitation power supply and Cellular Modem

IL-80 mounted in Enc300 with BPB-1 BBus Power Booster, PSM-2 Sensor Excitation power supply and Cellular Modem

End view of Enc300 showing typical wiring egress holes for gland fittings.

End view of Enc300 showing typical wiring egress holes for gland fittings.

Enc300 with WiFi Bridge, PSM-2 and AGM rechargeable batteries under hinged retaining assembly.

Enc300 with WiFi Bridge, PSM-2 and AGM rechargeable batteries under hinged retaining assembly.

Enc300 with AGM battery retainer hinged open.

Enc300 with AGM battery retainer hinged open.

Product Information

Overview

The IntelliLogger can be provided in the NEMA-4x equivalent rugged weather and tamperproof Enc300 enclosure for installation in demanding environments. A silicone gasketed door and sealing gland fittings effect a near water-tight seal* with jacketed wiring.

The basic Enc300 option includes mounting of the IntelliLogger base on a slide-out plate and machined holes for wiring gland fittings. The Enc300 can be configured with optional ancillary components (cell modem, batteries, etc) to build a self-contained data acquistion system. The unit can be portable applications or permanently surface mounted with the optional surface mount bracket for long term monitoring, reporting and alarming applications.

The Enc300 enclosure is the medium sized enclosure option for the IntelliLogger system and can typically house an IntelliLogger base as well as three to four additional ILIM-x Expansion Modules depending on the other ancillary installed components. Contact Logic Beach Technical Support for assistance in selecting the desired components and enclosure.

*Note: System is NEMA-4x equivalent and is not designed for complete immersion.

Options

  • Wall/surface mounting bracket Aluminum bracket mounts to the back of the Enc300 enclosure providing a flange at the top and bottom of the enclosure with mounting holes for wall or other surface securement.



  • Ethernet Cabling Egress For hardwired Ethernet connected IntelliLoggers, a machined hole and mating Gland Fitting facilitates installation of hardwired Cat5/6 Ethernet cable into ILEncXXX enclosure.




  • Non-licensed spread spectrum radios for point to point or point to multi-point instrument arrays – Contact Logic Beach Technical Support to discuss your special application packaging needs.

  • Custom wiring and integration – Contact Logic Beach Technical Support to discuss your special application packaging needs.

  • System Integration labor charge – Depending on the Enc250 configuration, there may be a nominal System Integration labor charge. Logic Beach Technical Support will advise charge after Enc250 configuration is defined.

Frequently Asked Questions

  • What materials are used in the enclosure construction?
    • ABS plastic (molded enclosure), silicone (door seal) and stainless fasteners.

  • What components can be installed in the Enc300 enclosure?
    • Typically, the Enc300 will contain an IL-10 or an IL-20, IL-80 or IL-90 and one additional ILIM-x Expansion Module in the base. The lid surface can then be used for mounting of terminal strip, cell modem, SCC-1, PSM-2 power supply, spread spectrum radios, etc.
    • Logic Beach commonly works with customers that have special application packaging needs to implement a semi-custom solution. Contact Logic Beach directly to discuss your special requirements.

  • What sensor and power wiring cable is suggested?
    • Jacket cabling seals most securely to the compression gland fittings on the bottom end of the enclosure.

  • Is the enclosure lockable?
    • Yes, there are lock loops molded into the enclosure into which a padlock can be installed to deter tampering.

Ordering

IntelliLogger IL-300 Enclosure
Product Name: IntelliLogger IL-300 Enclosure
Order Part Number: 8050.91300
Price: $320
|
Items included with Product:
Product Name:  Part Number: Qty:
Enclosure, 300 class, prepped for IntelliLogger mounting. Size: 12″w x 18″h x 7″d 8050.91300  1
Liquid Tight Fitting with Nut 3522.15003  12
Hole Plug for unused fittings 3522.95022  12
|
Items commonly purchased with this product:
Product Name: Order Part Number: Price:
ENC300 enclosure surface mounting bracket 3539.00004 $32
Cellular Modem for remote site communication 9080.5046x $499
D-Cell battery pack 8050.91215 $75

Contact Logic Beach directly to purchase this product.

Contact Logic Beach directly via phone or email with questions and/or to place your order.
Our Applications Staff welcomes your inquiry!