Modbus RTU Slave for the IL-Mini™

///Modbus RTU Slave for the IL-Mini™
Modbus RTU Slave for the IL-Mini™ 2017-07-14T12:30:43+00:00

Modbus RTU Slave for the IntelliLogger IL-Mini™ Option

For sharing IntelliLogger IL-Mini™ Modbus RTU Registers with a Master Device

Modbus RTU Slave Option Benefits
Share ILL internal registers with RTU Master devices
Connected RTU Master devices can Read and Write ILL registers
Flexible and Simple configuration of Slave register parameters

Product Information

Overview

Modbus RTU Slave Option for IntelliLogger IL-Mini™

An IL-Mini™ equipped with the Modbus Slave option and connected to a Modbus network can be programmed to expose internal Register values to connected Modbus Master devices (e.g. controllers, displays, etc). With this feature, the IntelliLogger IL-Mini™ can be sampling temperatures, pressures, flows, etc from hardwired inputs… performing calculations and also serving the Register values to a connected Master device over the Modbus RTU network.

Configuration of the Registers is simply done from within the HyperWare-II icon-based programming environment. Register addresses are assigned to each of the icons within the Program Net for which register value sharing with a connected Modbus Master device is desired.

IntelliLogger IL-Mini™ Modbus Registers can be configured to allow a Master device to access the following IntelliLogger IL-Mini™ parameters:

Current Value Readings

Current values, whether they be analog input signals, calculated values, event states or any other I/O parameter can be read from the IntelliLogger IL-Mini™. Modbus access is implemented by the addition of Probe Point icons into the IntelliLogger IL-Mini™ Program Net and then assignment of a Modbus register number to the Probe Point.

Remote Contol Icon State Update

Remote Control (On/Off) icon states within the IntelliLogger IL-Mini™ Program Net can be updated by writing to IntelliLogger IL-Mini™ Modbus Registers . This facilitates remote On/Off control of actions within the IntelliLogger IL-Mini™ from a remote instrument over the Modbus link. These On/Off actions can change the operation of the IntelliLogger IL-Mini™ program while it is running as well as control physical outputs on the IntelliLogger IL-Mini™.

Remote Constant Update

Upon command from a Modbus Master device, the Remote Constant icon within an IntelliLogger IL-Mini™ Program Net can be updated. This allows a remote Modbus Master device to change set-points, alarms, constants used in calculations, etc via the Modbus link.

The IntelliLogger IL-Mini™ can now be ordered with the following Modbus support options: