Modbus RTU Slave

Modbus RTU Slave 2017-07-14T12:13:11+00:00

Modbus RTU Slave Option

For sharing IntelliLogger™ Modbus RTU Registers with a Master Device

Modbus RTU Slave Option Benefits
Share ILL internal registers with RTU Master devices
Connected RTU Master devices can Read and Write ILL registers
Flexible and Simple configuration of Slave register parameters

Product Information

Overview

Modbus RTU Slave Option

IntelliLoggers equipped with this option and connected to a Modbus network can be programmed to expose internal Register values representing the different parameters to connected Modbus Master devices (e.g. controllers, displays, etc). With this feature, the IntelliLogger can be sampling temperatures, pressures, flows, etc from hardwired inputs… performing calculations and also serving the Register values to a connected Master device over the Modbus RTU network.

Configuration of the Registers is simply done from within the HyperWare-II icon-based programming environment. Register addresses are assigned to each of the icons within the Program Net for which register value sharing with a connected Modbus Master device is desired.

IntelliLogger Modbus Registers can be configured to allow a Master device to access the following IntelliLogger parameters:

Current Value Readings

Current values, whether they be analog input signals, calculated values, event states or any other I/O parameter can be read from the IntelliLogger. Modbus access is implemented by the addition of Probe Point icons into the IntelliLogger Program Net and then assignment of a Modbus register number to the Probe Point.

Remote Contol Icon State Update

Remote Control (On/Off) icon states within the IntelliLogger Program Net can be updated by writing to IntelliLogger Modbus Registers . This facilitates remote On/Off control of actions within the IntelliLogger from a remote instrument over the Modbus link. These On/Off actions can change the operation of the IntelliLogger program while it is running as well as control physical outputs on the IntelliLogger.

Remote Constant Update

Upon command from a Modbus Master device, the Remote Constant icon within an IntelliLogger Program Net can be updated. This allows a remote Modbus Master device to change set-points, alarms, constants used in calculations, etc via the Modbus link.

Documentation

Modbus Option Overview

Frequently Asked Questions

Ordering

IntelliLogger Modbus RTU Slave Option, software
Product Name: IntelliLogger Modbus RTU Slave Option, software
Order Part Number: MRS Option
Price: $220 (Note that a field update option is available for an $80 adder. Update file will be emailed)
|
Items included with order:
Product Name:  Part Number: Qty:
Intellilogger Modbus RTU Slave Option, software MRS Option  1
|
Items commonly purchased with this product:
Product Name: Order Part Number: Price:
SCC-1 Serial Comm Converter for Modbus RS-485 9080.50100 $128

Contact Logic Beach directly to purchase this product.

Contact Logic Beach directly via phone or email to with questions and/or to place your order.
Our Applications Staff welcomes your inquiry!

Accessories

SCC-1 Serial Comm Converter

Converts ILL RS-232 port to RS-485 for Modbus RTU applications.