Modbus RTU Slave Option
For sharing IntelliLogger™ Modbus RTU Registers with a Master Device
Modbus RTU Slave Option Benefits | |
---|---|
Share ILL internal registers with RTU Master devices | |
Connected RTU Master devices can Read and Write ILL registers | |
Flexible and Simple configuration of Slave register parameters |
Product Information
Overview
Modbus RTU Slave Option
IntelliLoggers equipped with this option and connected to a Modbus network can be programmed to expose internal Register values representing the different parameters to connected Modbus Master devices (e.g. controllers, displays, etc). With this feature, the IntelliLogger can be sampling temperatures, pressures, flows, etc from hardwired inputs… performing calculations and also serving the Register values to a connected Master device over the Modbus RTU network.
Configuration of the Registers is simply done from within the HyperWare-II icon-based programming environment. Register addresses are assigned to each of the icons within the Program Net for which register value sharing with a connected Modbus Master device is desired.
IntelliLogger Modbus Registers can be configured to allow a Master device to access the following IntelliLogger parameters:
Current Value Readings
Current values, whether they be analog input signals, calculated values, event states or any other I/O parameter can be read from the IntelliLogger. Modbus access is implemented by the addition of Probe Point icons into the IntelliLogger Program Net and then assignment of a Modbus register number to the Probe Point.
Remote Contol Icon State Update
Remote Control (On/Off) icon states within the IntelliLogger Program Net can be updated by writing to IntelliLogger Modbus Registers . This facilitates remote On/Off control of actions within the IntelliLogger from a remote instrument over the Modbus link. These On/Off actions can change the operation of the IntelliLogger program while it is running as well as control physical outputs on the IntelliLogger.
Remote Constant Update
Upon command from a Modbus Master device, the Remote Constant icon within an IntelliLogger Program Net can be updated. This allows a remote Modbus Master device to change set-points, alarms, constants used in calculations, etc via the Modbus link.
Accessories
SCC-1 Serial Communication Converter
Documentation
Modbus Option Overview
Frequently Asked Questions
Ordering
IntelliLogger Modbus RTU Slave Option, software | |||
---|---|---|---|
Product Name: | IntelliLogger Modbus RTU Slave Option, software | ||
Order Part Number: | MRS Option | ||
Price: | $220 (Note that units can be updated in the field with this option for an $80 additional surcharge. Feature updating file will be emailed) | ||
| | |||
Items included with order: | |||
Product Name: | Part Number: | Qty: | |
Intellilogger Modbus RTU Slave Option, software | MRS Option | 1 | |
| | |||
Items commonly purchased with this product: | |||
Product Name: | Order Part Number: | Price: | |
SCC-1 Serial Comm Converter for Modbus RS-485 | 9080.50100 | $128 |
Contact Logic Beach directly to purchase this product.
Contact Logic Beach directly via phone or email with questions and/or to place your order.
Our Applications Staff welcomes your inquiry!
Accessories
SCC-1 Serial Comm Converter
Converts ILL RS-232 port to RS-485 for Modbus RTU applications.