Back to Sensors Guide |
Logic Beach distributes a full line of rugged, industrial quality pressure transducers to assist our customers in assembling complete data acquisition solutions. All products are 316 stainless steel construction and can be provided with a wide range of full scale pressures, accuracies, process connections, signal outputs and wiring connections.
Parts that are commonly used by our customers are documented below along with some specific part numbers that typically can ship from stock.
Contact Logic Beach for special requirements in parts not shown.
All listed parts have a 3 year manufacturer’s warranty.
615 Series – Very High Accuracy (0.25% FS or 0.125% FS), field zero/span adj
100 Series – High Accuracy (0.5%FS), 4-20mA output, field zero/span adj
200 Series – High Accuracy (0.5%FS), Vdc output, field zero/span adj.
300 Series - High Accuracy (0.5% FS), rugged, 4-20mA output, fixed calibration
615 Series Pressure Transducers [Series 615 Data Sheet]
The 615 series of pressure transducers offers extremely rugged packaging and very high accuracy of 0.25% FS (standard) and 0.125% FS (optional). Units feature field adjustable Zero and Span, novel IP-65 Hirschman fittings for sealed field wiring connections to jacketed wire.
STOCK 615 MODEL SPECIFICATIONS |
Output signals |
4 mA to 20 mA, 2 wire
1 Vdc to 5 Vdc, 3 wire
1 Vdc to 6 Vdc, 3 wire
1 Vdc to 11 Vdc, 3 wire
0 Vdc to 5 Vdc, 3 wire
0 Vdc to 10 Vdc, 3 wire
0 Vdc to 5 Vdc , 4 wire
0 Vdc to 10 Vdc, 4 wire |
Pressure ranges |
Standard gauge ranges from vacuum through 120000 psi;
Standard absolute ranges from 15 psia to 300 psia |
Proof pressure |
3 times Full Scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
1.75 times Full Scale for ranges 0 psi to 300 psi through 0 psi to 10000 psi
1.5 times Full Scale for 0 psi to 15000 psi range
1.5 times Full Scale for ranges 0 psi to 20000 psi through 0 psi to 120000 psi |
Burst pressure |
3.8 times Full Scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
4 times Full Scale for ranges 0 psi to 300 psi through o psi to 10000 psi
3 times Full Scale for 0 psi to 15000 psi range
1.5 times Full Scale for ranges 0 to 20000 psi through 0 to 120000 psi |
Accuracy |
± 0.25 % Full Scale (Best Fit Straight Line)
(Includes the combined effects of linearity, hystersis and repeatability)
± 0.125 % Full Scale (optional) |
Repeatability |
≤ ± 0.05 % Full Scale |
Hysteresis |
≤ ± 0.1 % Full Scale |
Stability |
≤ ± 0.2 % Full Scale per year, non accumulating |
Power supply |
10 Vdc to 30 Vdc for current output
14 Vdc to 30 Vdc for voltage output |
Load limitations |
≤ (V Power Supply – 10 Vdc) / 0.020 Amp for 4 mA to 20 mA
10,000 Ω for 0 Vdc to 10 Vdc, 3 wire
5,000 Ω for 0 Vdc to 5 Vdc, 3 wire |
Wetted materials |
316 stainless steel for vacuum through 300 psi; 17-4PH stainless steel
sensing diaphragm and 316 stainless steel pressure connection for
higher ranges |
Housing materials |
316 stainless steel |
Temperature ranges |
Compensated 32 °F to 175 °F (0 °C to 80 °C)
Effect ± 0.01 % / °F to zero point and pressure range
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Medium -20 °F to 212 °F (-30 °C to 100 °C)
Ambient -15 °F to 175 °F (-10 °C to 80 °C) |
Response time |
Less than 1 ms (between 10 % to 90% Full Scale) |
Durability |
>100 million Full Scale Cycles |
Adjustment |
±10 % Full Scale of zero and span |
Enviromental protection |
NEMA 4x, IP65 (IEC 529) |
Electromagnetic rating |
CE compliant to EMC norm EN61326: 1997/A1: 1998
RFI, EMI and ESD protection |
Electrical protection |
Reverse polarity, overvoltage and short circuit protection |
Shock |
Less than ± 0.05% Full Scale effect or 100 g's @ 20ms on any axis |
Vibration |
Less then ± 0.01% Full Scale effect for 15 g's @ 0 to 2000 Hz on any axis |
Weight |
Approximately 7.2 oz |
615 Series Commonly Sourced Part Numbers:
The following part numbers are commonly stocked for fast delivery. Many options exist for full scale pressure range, signal output, process connection fittings, field wiring termination, etc. Contact Logic Beach for special needs.
Part |
Description |
PSIG-615-0.125%-xxx-4-20-1/4"MNPT |
0.125% FS accuracy, 4-20mA output, Field adjustable Zero/Span, 1/4" male pipe thread media fitting. |
|
|
PSIG-615-0.25%-xxx-4-20-1/4"MNPT |
0.25% FS accuracy, 4-20mA output, Field adjustable Zero/Span, 1/4" male pipe thread media fitting. |
|
|
PSIG-615-0.25%-xxx-Vdc-1/4"MNPT |
0.25% FS accuracy, 0-1Vdc output, Field adjustable Zero/Span, 1/4" male pipe thread media fitting. |
| Note: xxx in Part Number refers to full scale pressure range. Available ranges include: 2,3,5,10,15,30,60,100,150,200,300,500, 600, 750, 1000, 1500, 2000, 3000, 4000, 5000, 6000, 7500, 10,000, 15,000 PSIG |
|

615 Series Pressure Transducer
|
100 Series 4-20mA Output Pressure Transducers [Series 100 Data Sheet]
The 100 series of 4-20mA output pressure transducers offers extremely rugged packaging and high accuracy of 0.5% FS accuracy. Units feature field adjustable Zero and Span, novel IP-65 Hirschman fittings for sealed field wiring connections to jacketed wire.
Series 100 and 200 Specifications |
Output signal |
4 mA to 20 mA, 2 wire |
Pressure ranges |
Standard gauge ranges from vacuum to 15000 psi; Standard
Absolute ranges from 15 psia to 300 psia |
Proof pressure |
3 times Full Scale for ranges 0 psi to 5 psi through 0 to 200 psi
1.75 times Full Scale for ranges 0 psi to 300 psi through 0 to 10000 psi
1.5 times Full Scale for 0 psi to 15000 psi range |
Burst pressure |
3.8 times Full Scale for ranges 0 psi to 5 psi through 0 to 200 psi
4 times Full Scale for ranges 0 psi to 300 psi through 0 to 10000 psi
3 times Full Scale for 0 psi to 15000 psi range |
Accuracy |
± 0.5 % Full Scale (Best Fit Straight Line); ±0.25 % optional
(Includes the combined effects of linearity, hysteresis and repeatablility) |
Repeatabiliy |
≤ ±0.05 % Full Scale |
Hysteresis |
≤±0.1 % Full Scale |
Stability |
≤±0.2 % Full Scale for 1 year, non-accumulating |
Response time |
≤1 ms (between 10 % and 90 % Full Scale) |
Power supply |
10 Vdc to 30 Vdc, unregulated |
Load limitations |
Load in resistance must be ≤ (V power supply - 10) / 0.020 Amp |
Wetted materials |
316 stainless steel for vacuum through 300 psi;17-4PH
stainless steel sensing diaphragm and 316 stainless steel
pressure connection for higher ranges |
Housing material |
316 stainless steel |
Adjustments |
±10 % Full Scale for zero and span |
Pressure cycle limit |
150 Hz |
Durability |
> 100 million full Scale cycles |
Temperature ranges |
Compensated 32 °F to 176 °F (0 °C to 80 °C)
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Media -22°F to 212 °F (-30 °C to 100 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C) |
Environmental rating |
IP65, NEMA 4X according to EN 60529/IEC 529 |
Electromagnetic rating |
CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection |
Electrical protection |
Reverse polarity, over-voltage and short circuit protection |
Shock resistance |
1000 g’s per IEC 60770-1 |
Vibration resistance |
30 g’s per IEC 60770-1 |
Weight |
Approximately 3.5 oz |
100 Series Commonly Sourced Part Numbers:
The following part numbers are commonly stocked for fast delivery. Many options exist for full scale pressure range, signal output, process connection fittings, field wiring termination, etc. Contact Logic Beach for special needs.
Part |
Description |
PSIG-100-0.5%-xxx-4-20-1/4"MNPT |
0.5% FS accuracy, 4-20mA output, Field adjustable Zero/Span, 1/4" male pipe thread media fitting. |
| Note: xxx in Part Number refers to full scale pressure range. Available ranges include: 2,3,5,10,15,30,60,100,150,200,300,500, 600, 750, 1000, 1500, 2000, 3000, 4000, 5000, 6000, 7500, 10,000, 15,000 PSIG |
|

100 Series Transducer |
The 200 series is identical to the 100 series but equipped with Vdc output (vs the 4-20mA output). These pressure transducers offers extremely rugged packaging and high accuracy of 0.5% FS accuracy. Units feature field adjustable Zero and Span, novel IP-65 Hirschman fittings for sealed field wiring connections to jacketed wire.
STOCK MODEL SPECIFICATIONS |
Output Signal |
0 Vdc to 5 Vdc, 3 wire
0 Vdc to 10 Vdc, 3 wire
1 Vdc to 5 Vdc, 3 wire
1 Vdc to 6 Vdc, 3 wire
1 Vdc to 11 Vdc, 3 wire |
Pressure Ranges |
Standard gauge ranges from vacuum to 15000 psig;
Standard absolute ranges from 15 psia to 300 psia |
Proof Pressure |
3 times Full Scale for ranges 0 to 5 psi through 0 to 200 psi
1.75 times Full Scale for ranges 0 to 300 psi through 0 to 10000 psi
1.5 times Full Scale for 0 to 15000 psi range |
Burst Pressure |
3.8 times Full Scale for ranges 0 to 5 psi through 0 to 200 psi
4 times Full Scale for ranges 0 to 300 psi through 0 to 10000 psi
3 times Full Scale for 0 to 15000 psi range |
Accuracy |
± 0.5 % Full Scale (Best Fit Straight Line);
± 0.25 % Full Scale optional
(Includes the combined effects of linearity, hysteresis and repeatability) |
Repeatability |
≤ ± 0.05 % Full Scale |
Hysteresis |
≤ ± 0.1 % Full Scale |
Stability |
≤ ± 0.2 % Full Scale per year, non- accumulating |
Response time |
≤ 1 ms (between 10% to 90% Full Scale) |
Power supply |
10 Vdc to 30 Vdc, 14 Vdc to 30 Vdc for 1 Vdc to 11 Vdc and 0 Vdc to 10 Vdc unregulated |
Load limitations |
Load in resistance must be ≥ 5000 Ω for 0 Vdc to 5 Vdc, 1 Vdc
to 5 Vdc, and 1 Vdc to 6 Vdc outputs; load in resistance must be
≥ 10000 Ω for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs |
Wetted materials |
316 stainless steel for vacuum through 300 psi;17-4PH
stainless steel sensing diaphragm and 316 stainless steel
pressure connection for higher ranges Current consumption 8 mA |
Housing material |
316 stainless steel |
Adjustment |
±10 % Full Scale for zero and span |
Pressure cycle limit |
150 Hz |
Durability |
> 100 million cycles |
Temperature ranges |
Compensated 32 °F to 176 °F (0 °C to 80 °C)
Zero effect ±0.017 % Full Scale/°F
Span effect ±0.017 % Full Scale/°F
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Media -22 °F to 212 °F (-30 °C to 100 °C) |
Environmental rating |
IP65, NEMA 4X according to EN 60529/IEC 529; |
Electromagnetic rating |
CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection |
Electrical protection |
Reverse polarity, over-voltage and short circuit protection |
Shock resistance |
1000 g’s per IEC 60770-1 |
Vibration resistance |
30 g’s per IEC 60770-1 |
Weight |
Approximately 3.5 oz |
Part |
Description |
PSIG-200-0.5%-xxx-4-20-1/4"MNPT |
0.5% FS accuracy, 0-5Vdc output, Field adjustable Zero/Span, 1/4" male pipe thread media fitting. |
| Note: xxx in Part Number refers to full scale pressure range. Available ranges include: 2,3,5,10,15,30,60,100,150,200,300,500, 600, 750, 1000, 1500, 2000, 3000, 4000, 5000, 6000, 7500, 10,000, 15,000 PSIG |
|

200 Series Transducer
|
300 Series 4-20mA Output Pressure Transducers
The new, economical 300 series of 4-20mA output pressure transducers offers extremely rugged packaging and high accuracy of 0.5% FS accuracy. Units feature novel IP-65 Hirschman fittings for sealed field wiring connections to jacketed wire. Calibration is fixed at time of manufacture (no field zero/span adjustment).
STOCK MODEL SPECIFICATIONS |
Output Signal |
4 mA to 20 mA,
2-wire
0 Vdc to 5 Vdc, 3-wire
1 Vdc to 5 Vdc, 3-wire
0 Vdc to 10 Vdc, 3-wire
0.5 Vdc to 4.5 Vdc ratiometric, 3-wire |
Pressure Ranges |
Standard gauge ranges from 0 psig to 15 psig; through psig to 10,000 psig
Standard absolute ranges 15 psig through 200 psig |
Proof Pressure |
2 times Full Scale |
Burst Pressure |
6 times Full Scale |
Accuracy |
±0.5 % Full Scale (Best Fit Straight Line); ±0.25 % optional
(Includes the combined effects of linearity, hysteresis and repeatability) |
Repeatability |
≤ ±0.05 % Full Scale |
Hysteresis |
≤ ±0.1 % Full Scale |
Stability |
≤ ±0.2 % Full Scale per year, non-accumulating |
Response time |
≤ 4 ms (between 10 % and 90 % Full Scale) |
Power supply |
8 Vdc to 30 Vdc unregulated for 4 mA to 20 mA output, 0 Vdc to 5 Vdc
output and 1 Vdc to 5 Vdc outputs; 5 Vdc ±0.5 Vdc for 0.5 Vdc to 4.5 Vdc
output |
Load limitations |
≤ (VPower -10)/0.020 Amp for 4 mA to 20 mA output
>5.000 ⏐ for 1 Vdc to 5 Vdc output
>10,000 ⏐ for 0 Vdc to 10 Vdc output
>4,500 ⏐ for 0.5 Vdc to 4.5 Vdc output |
Wetted materials |
316 stainless steel for absolute through 150psi
13-8PH stainless steel sensing diaphragm and 316 stainless steel process
connection for higher ranges |
Housing material |
316L stainless steel |
Adjustment |
|
Pressure cycle limit |
150 Hz |
Durability |
> 100,000,000 Full Scale cycles |
Temperature ranges |
Compensated 32 °F to 176 °F (0 °C to 80 °C)
Storage -4°F to 176°F (0°C to 80°C)
Media 32°F to 176°F (0°C to 80°C)
Ambient 32°F to 176°F (0°C to 80°C) |
Environmental rating |
IP65 to IP67 depending on electrical connection |
Electromagnetic rating |
CE compliant to EMC norm EN61326: 1997/A1: 1998
RFI, EMI and ESD protection |
Electrical protection |
Reverse polarity, over-voltage and short circuit protection |
Shock resistance |
100 g’s per IEC 68-2-27 |
Vibration resistance |
10 g’s per IEC 68-2-6 |
Weight |
Approximately 2.8 oz. |
300 Series Commonly Sourced Part Numbers:
The following part numbers are commonly stocked for fast delivery. Many options exist for full scale pressure range, signal output, process connection fittings, field wiring termination, etc. Contact Logic Beach for special needs.
Part |
Description |
PSIG-300-0.5%-xxx-4-20-1/4"MNPT |
0.5% FS accuracy, 4-20mA output, Fixed calibration. 1/4" male pipe thread media fitting. |
| Note: xxx in Part Number refers to full scale pressure range. Available ranges include: 2,3,5,10,15,30,60,100,150,200,300,500, 600, 750, 1000, 1500, 2000, 3000, 4000, 5000, 6000, 7500, 10,000, 15,000 PSIG |
|

Series 300 with various wiring options
|
|
|
|

Data
Logger Selection Guide | Data Logger Applications | Data Sheets and Downloads | Testimonials | About Logic Beach | Contact
| Sitemap
Logic Beach, Incorporated
8363-6F Center Drive
La Mesa, CA 91942
Phone: (619) 698-3300 |
Fax: (619) 469-8604
Logic Beach, Inc, All Rights Reserved, Copyright © 2010 |