Variety of ranges,
outputs and accessories are available from Logic Beach.
From 10 Amps to 2400 Amps, we have a current sensor for
your application. Current sensors are available with DC
Voltage or DC current outputs making them ideal for use
with any of our data loggers configured with an analog inputs.
Any of the CTs requiring excitation voltage can be paired
with our PSM-2 power supply module that delivers a regulated
5, 10, 15 or 24vDC.
Using the programming
power of HyperWare and our current sensors, you can easily
calculate kW and kWh just from one current input and a measured
voltage.
Small split-core self-powered current transformer. Fully isolated and reverse output polarity protected. Average sensing, RMS calibrated. Three current ranges where X=current range. Two output options where V specifies 2 or 5Vdc output. Size: 1" x 1.25" x 2"
Split-core current transformer,
loop powered, self-gripping, 3 DIP switch selectable
ranges 0-30/60/120 A. Size: 2.9" x 2.6"
x 1.0"
Range
Output
Hz
Accuracy
Operating Voltage
0-30-60-120
4-20mA
60
2%FS
600 VAC
P/N
LBI-H922
Description:
Split-core current transformer,
self-gripping,self-powered, 3 DIP switch selectable
ranges 0-30/60/120 A. Size: 3.1" x 2.2"
x 1.0"
Range
Output
Hz
Accuracy
Operating Voltage
0-30-60-120
0-5V
DC
50/60
2%FS
600 VAC RMS
P/N
LBI-H221
Description:
High Amperage split core design
with proportional 4-20mA loop powered. Zero and
span adjustment. 12-30Vdc @ 30mA. Supply Voltage:
UL. Size: 3.9" x 3.75" x 1.1"
Range
Output
Hz
Accuracy
Operating Voltage
0-300A
4-20mA
60
2%
FS all scales
600 VAC
P/N
LBI-H321
Description:
High Amperage split core with
proportional 4-20mA loop powered. Zero and span
adjustment. 12-30Vdc @ 30mA. Supply Voltage: UL.
Size: 5.2" x 4.9" x 1.1".
Range
Output
Hz
Accuracy
Operating Voltage
0-800A
4-20mA
60
2%
FS all scales
600 VAC
P/N
LBI-H421
Description:
High Amperage split core with
proportional 4-20mA loop powered. Zero and span
adjustment. Supply Voltage: 12-30 Vdc@30mA. Size: 7.9" x 4.9"
x 1.1"
Range
Output
Hz
Accuracy
Operating Voltage
0-2400A
4-20mA
60
2%
FS all scales
600 VAC
P/N
LBI-H822-10
Description:
AC current transformer, small
compact design. Donut-style with mounting clip.
Designed for low current loads. Self-Powered Size:
2.8" x 1.8"x1".
Range
Output
Hz
Accuracy
Operating Voltage
0-10A
0-5V
DC
60
2%
600 VAC
P/N
LBI-H822-20
Description:
AC current transformer, small
compact design. Donut-style with mounting clip.
Designed for low current loads. Self-Powered. Size:
2.8" x 1.8" x 1".
Range
Output
Hz
Accuracy
Operating Voltage
0.5-25A
0-5V
DC
60
2%
600 VAC
P/N
LBI-MN-291
Description:
Small clamp-on current probe w/leads.
EN 61010-2-32 rated, CE and UL listed. Size: 5.5"
x 2.0" x 1.2"
Range
Output
Hz
Accuracy
Operating Voltage
0.5A-240A
DC Voltage
100mV/ADC/AAC
40 to 10kHz
2.0%
to 3.0% depending upon range
600Vrms
P/N
LBI-MD-301
Description:
Medium clamp-on current probe
w/leads. EN 61010-2- 32 rated, CE Mark. Size: 2.6"
x 7.7" x 1.34"