RHT-1A rH + Temperature Sensor
|
Description:
The RHT-1A Relative Humidity probe is an inexpensive,
wide input range, low-power humidity and temperature sensor.
The RHT-1A contains a rugged capacitive humidity sensing element
and a precision RTD for temperature sensing. The unit can measure
RH from 0 to 98% and temperature from -10 to 60°C (14 to
140°F).
The RHT-1A is of cylindrical shape with
an M8 quick connector and 1' cable. The sensing element is field
replaceable and is protected from dirt and grit by an integral
membrane filter. The
probe can withstand direct immersion and will recover to factory
specifications after drying.
See the Data
Logger Selection Guide for help with locating the appropriate
instrument for your inputs.
|
Data logger Interface:
The RHT-1A provides a linear 0 to 5Vdc output corresponding
to 0 to 100% relative humidity. For temperature sensing a second output
is provided which has a linear 0 to 5Vdc output corresponding to -40°
to 60°C.
These sensed signals can be directly connected to the ModuLogger "Mini"
analog inputs, the ModuLogger System Base or MLIM-1 Interface Modules
and/or the HyperLogger HLIM-1 Interface Modules input channels.
Scaling and other desired data manipulation is readily handled in
the programming of the logger using the powerful HyperWare software.
The unit can be powered from a DC source in the range of 7 to 28Vdc
and stabilizes in 150 mS. Due to its quick stabilization after power-up,
the unit can be powered on just prior to taking a reading, sampled,
then powered off to conserve logger battery energy. The unit can be
powered directly by the ModuLogger, Mini, or HyperLogger system
batteries (optionally switched through a logger output relay) or from
a PSM-2 Power Supply Module
in conjunction with any of the Logic Beach data logging systems.
Specifications
| Operating Temperature: |
-10 to 60°C |
| RH Accuracy: |
+/-3% over 0 to 90%RH, +/- 5% 90-98% |
|
RH Measurement Range:
|
0 to 98%RH |
| RH Stability (over time): |
better than +/-2% over 2 years |
| Temp Accuracy: |
+/- 0.6°C
at 20°C |
| Temp Measurement Range : |
-10 to 60°C |
| Temp Range (storage): |
-40 to 60°C |
| Probe Excitation Voltage: |
7 to 28 Vdc |
| Current Consumption: |
2 mA |
| Output Signal: |
0 to 5 Vdc corresponding to 0 to 100%RH and
-40°
to 60°
C |
| Probe Dimensions: |
0.47" dia, 2.7 " long |
| Termination: |
M8 connector to 1' cable |
|
|
|

Data
Logger Selection Guide | Data Logger Applications | Data Sheets and Downloads | Testimonials | About Logic Beach | Contact
Logic Beach, Incorporated
8363-6F Center Drive
La Mesa, CA 91942
Phone: (619) 698-3300 |
Fax: (619) 469-8604
Logic Beach, Inc , All Rights
Reserved, Copyright © 2008
|