Glossary
of Terms - Use
Find, Edit / Find (ctrl F) to find your word.
Absolute Pressure Transducer: A transducer which measures
pressure in relation to zero pressure (a vacuum on one side of the
diaphragm).
Absolute Pressure: Gage pressure plus atmospheric
pressure.
Absolute Zero: Temperature at which thermal
energy is at a minimum. Defined as 0 Kelvin, calculated to be -273.15°C
or -459.67°F.
ac: Alternating current; an electric
current that reverses its direction at regularly recurring intervals.
Acceleration: A change in the velocity of
a body or particle with respect to time. The parameter that an accelerometer
measures (dv/dt). Units expressed in "g".
Accelerometer: A device which converts the
effects of mechanical motion into an electrical signal that is proportional
to the acceleration value of the motion. A sensor. A transducer.
Accuracy: The closeness of an indication
or reading of a measurement device to the actual value of the quantity
being measured. Usually expressed as ± percent of full scale output
or reading.
ADC: Analog-to-Digital Converter:
an electronic device which converts analog signals to an equivalent
digital form, in either a binary code or a binary-coded-decimal code.
When used for dynamic waveforms, the sampling rate must be high to
prevent aliasing errors from occurring.
Aliasing: If the sample rate of a function
(fs) is less than two times the highest frequency value of the function,
the frequency is ambiguously presented. The frequencies above (fs/2)
will be folded back into the lower frequencies producing erroneous
data.
Ambient Compensation: The design of an instrument
such that changes in ambient temperature do not affect the readings
of the instrument.
Ambient Conditions: The conditions around the transducer
(pressure, temperature, etc.).
Ambient Pressure: Pressure of the air surrounding
a transducer.
Ambient Temperature: The
average or mean temperature of the surrounding air which comes in
contact with the equipment and instruments under test.
Ampere (amp): A unit used to define the rate
of flow of electricity (current) in a circuit; units are one coulomb
(6.25 x 108 electronics) per second.
Amplifier: A
device which draws power from a source other than the input signal
and which produces as an output an enlarged reproduction of the essential
features of its input.
Amplitude Span: The Y-axis range of a graphic
display of data in either the time or frequency domain. Usually a
log display (dB) but can also be linear.
Amplitude: A
measurement of the distance from the highest to the lowest excursion
of motion, as in the case of mechanical body in oscillation or the
peak-to-peak swing of an electrical waveform.
Analog Output: A voltage or current signal
that is a continuous function of the measured parameter.
Analog-to-Digital Converter
(A/D or ADC): A device or circuit that outputs a binary number corresponding to
an analog signal level at the input.
Anemometer: An instrument for measuring
and/or indicating the velocity of air flow.
ANSI: American National Standards
Institute.
Application Program: A
computer program that accomplishes specific tasks, such as word processing.
ASCII: American Standard Code for
Information Interchange. A seven or eight bit code used to represent
alphanumeric characters. It is the standard code used for communications
between data processing systems and associated equipment.
ASME: American Society of Mechanical
Engineers.
ASTM: American Society for Testing
and Materials.
Asymmetry Potential: The potential developed across
the glass membrane with identical solutions on both sides. Also a
term used when comparing glass electrode potential in pH 7 buffer.
Asynchronous: A communication method where
data is sent when it is ready without being referenced to a timing
clock, rather than waiting until the receiver signals that it is ready
to receive.
ATC: Automatic temperature compensation.
Auto-Zero: An automatic internal correction
for offsets and/or drift at zero voltage input.
AWG: American Wire Gage.
Background Noise: The total noise floor from
all sources of interference in a measurement system, independent of
the presence of a data signal.
Bandwidth: A symmetrical region around
the set point in which proportional control occurs.
Baud: A unit of data transmission
speed equal to the number of bits (or signal events) per second; 300
baud = 300 bits per second.
Bipolar: The ability of a panel meter
to display both positive and negative readings.
Bit: Acronym for binary digit. The
smallest unit of computer information, it is either a binary 0 or
1.
BPS: Bits per second.
Breakdown Voltage Rating: The dc or ac voltage which
can be applied across insulation portions of a transducer without
arcing or conduction above a specific current value.
Bridge Resistance: See Input impedance and Output
impedance.
BTU: British thermal units. The
quantity of thermal energy required to raise one pound of water at
its maximum density, 1 degree F. One BTU is equivalent to .293 watt
hours, or 252 calories. One kilowatt hour is equivalent to 3412 BTU.
Buffer: 1. A storage area for data
that is used to compensate for a speed difference, when transferring
data from one device to another. Usually refers to an area reserved
for I/O operations, into which data is read, or from which data is
written.2. Any substance or combination of substances which, when
dissolved in water, produces a solution which resists a change in
its hydrogen ion concentration on the addition of an acid or alkali.
Burn-In: A long term screening test
(either vibration, temperature or combined test) that is effective
in weeding out infant mortalities because it simulates actual or worst
case operation of the device, accelerated through a time, power, and
temperature relationship.
Bus: Parallel lines used to transfer
signals between devices or components. Computers are often described
by their bus structure (i.e., S-100, IBM PC).
Byte: The representation of a character
in binary. Eight bits.
Cal-Chekä: Method developed by Logic Beach
for regular front end calibration of the data logging signal conditioning
input section. Precision trimmed
and temperature stabilized references insure accurate input modules
calibration.
Calibration: The
process of adjusting an instrument or compiling a deviation chart
so that its reading can be correlated to the actual value being measured.
Celsius (centrigrade): A temperature scale defined
by 0°C at the ice point and 100°C at boiling point of water at sea
level.
CFM: The volumetric flow rate of
a liquid or gas in cubic feet per minute.
Chatter: The rapid cycling on and off
of a relay in a control process due to insufficient bandwidth in the
controller.
CMR (Common-Mode Rejection): The ability of a panel meter
to eliminate the effect of AC or DC noise between signal and ground.
Normally expressed in dB at dc to 60 Hz. One type of CMR is specified
between SIG LO and PWR GND. In differential meters, a second type
of CMR is specified between SIG LO and ANA GND (METER GND).
CMV (Common-Mode Voltage): The AC or DC voltage which
is tolerable between signal and ground. One type of CMV is specified
between SIG LO and PWR GND. In differential meters, a second type
of CMV is specified between SIG HI or LO and ANA GND (METER GND).
Color Code: The ANSI established color
code for thermocouple wires in the negative lead is always red. Color
Code for base metal thermocouples is yellow for Type K, black for
Type J, purple for Type E and blue for Type T.
Common Mode Rejection Ratio: The ability of an instrument
to reject interference from a common voltage at its input terminals
with relation to ground. Usually expressed in db (decibels).
Common Mode: The output form or type of
control action used by a temperature controller to control temperature,
i.e. on/off, time proportioning, PID.
Compensation: An addition of specific materials
or devices to counteract a known error.
Complex Wave: The resultant form of a number
of sinusoidal waves that are summed together forming a periodic wave.
Such waves may be analyzed in the frequency domain to readily determine
their component parts.
Conductance: The
measure of the ability of a solution to carry an electrical current.
(See Equivalent Conductance)
Conduction: The conveying of electrical
energy or heat through or by means of a conductor.
Convection: 1. The circulatory motion that
occurs in a fluid at a non-uniform temperature owing to the variation
of its density and the action of gravity. 2. The transfer of heat
by this automatic circulation of fluid.
Counts: The number of time intervals
counted by the dual-slope A/D converter and displayed as the reading
of the panel meter, before addition of the decimal point.
CPS: Cycles per second; the rate
or number of periodic events in one second, expressed in Hertz (Hz).
CSA: Canadian Standards Administration.
Current Proportioning: An output form of a temperature
controller which provides a current proportional to the amount of
control required. Normally is a 4 to 20 milliamp current proportioning
band.
Current: The rate of flow of electricity.
The unit of the ampere (A) defined as 1 ampere = 1 coulomb per second.
Cycle Time: The time usually expressed
in seconds for a controller to complete one on/off cycle.
dB (Decibel): 20 times the log to the base
10 of the ratio of two voltages. Every 20 dBs correspond to a voltage
ratio of 10, every 10 dBs to a voltage ratio of 3.162. For instance,
a CMR of 120 dB provides voltage noise rejection of 1,000,000/1. An
NMR of 70 dB provides voltage noise rejection of 3,162/1.
DC: Direct current; an electric
current flowing in one direction only and substantially constant in
value.
Decimal: Refers to a base ten number
system using the characters 0 through 9 to represent values.
Density: Mass per unit of volume of
a substance. I.E.: grams/cu.cm. or pounds/cu.ft.
Deviation: The difference between the
value of the controlled variable and the value at which it is being
controlled.
Diaphragm: The sensing element consisting
of a membrane which is deformed by the pressure differential applied
across it.
Differential Input: A signal-input circuit where
SIG LO and SIG HI are electrically floating with respect to ANALOG
GND (METER GND, which is normally tied to DIG GND). This allows the
measurement of the voltage difference between two signals tied to
the same ground and provides superior common-mode noise rejection.
Differential Pressure: The difference in static pressure
between two identical pressure taps at the same elevation located
in two different locations in a primary device.
Differential: For an on/off controller, it
refers to the temperature difference between the temperature at which
the controller turns heat off and the temperature at which the heat
is turned back on. It is expressed in degrees.
Digital-to-Analog Converter
(D/A or DAC): A device or circuit to convert a digital value to an analog signal level.
Displacement: The measured distance traveled
by a point from its position at rest. Peak to peak displacement is
the total measured movement of a vibrating point between its positive
and negative extremes. Measurement units expressed as inches or millinches.
DMA: Acronym direct memory access.
A high speed data storage mode of the IBM PC.
Drift: A change of a reading or a
set point value over long periods due to several factors including
change in ambient temperature, time, and line voltage.
Duty Cycle: The total time to one on/off
cycle. Usually refers to the on/off cycle time of a temperature controller.
Electromotive Force (emf): The potential difference between
the two electrodes in a cell. The cell emf is the cell voltage measured
when no current is flowing through the cell. It can be measured by
means of a pH meter with high input impedance.
EMF: Electromotive force. A rise
in (electrical) potential energy. The principal unit is the volt.
EMI: Electromagnetic interference.
Environmental Conditions: All conditions in which a transducer
may be exposed during shipping, storage, handling, and operation.
Eprom: Erasable Programmable Read-Only
Memory. The PROM can be erased by ultraviolet light or electricity.
Excitation: The external application of
electrical voltage current applied to a transducer for normal operation.
Fahrenheit: A temperature scale defined
by 32° at the ice point and 212° at the boiling point of water at
sea level.
Firmware: Programs stored in PROMs.
Floppy Disk: A small, flexible disk carrying
a magnetic medium in which digital data is stored for later retrieval
and use.
Flow Rate: Actual speed or velocity of
fluid movement .
Flow: Travel of liquids or gases
in response to a force (i.e. pressure or gravity).
Flowmeter: A device used for measuring
the flow or quantity of a moving fluid.
FPM: Flow velocity in feet per minute.
FPS: Flow velocity in feet per second.
Freezing Point: The temperature at which the
substance goes from the liquid phase to the solid phase.
Frequency Output: An output in the form of frequency
which varies as a function of the applied input.
Frequency: The number of cycles over a
specified time period over which an event occurs. The reciprocal is
called the period.
Full Bridge: A Wheatstone bridge configuration
utilizing four active elements or strain gages.
Full Scale Output: The algebraic difference between
the minimum output and maximum output.
Gage Pressure Transducer: A transducer which measures
pressure in relation to the ambient pressure.
Gage pressure: Absolute
pressure minus local atmospheric pressure.
Gain: The amount of amplification
used in an electrical circuit.
GPH: Volumetric flow rate in gallons
per hour.
GPM: Volumetric flow rate in gallons
per minute.
Ground: 1. The electrical neutral line
having the same potential as the surrounding earth. 2. The negative
side of DC power supply. 3. Reference point for an electrical system.
Grounded Junction: A form of construction of a
thermocouple probe where the hot or measuring junction is in electrical
contact with the sheath material so that the sheath and thermocouple
will have the same electrical potential.
Half Bridge: Two active elements or strain
gages.
Hertz (Hz): Units in which frequency is
expressed. Synonymous with cycles per second.
HyperNetä: The icon-based programming environment
of HyperWare. Connect icons
together forming the program that runs within the data logger. Choose from up to 32 different icons representing,
sample rate clocks, math, logic, operational, data reduction and scheduling
functions.
HyperCommä: The communications environment of HyperWare. Allows for RS-232, modem, Ethernet and RF
link communications.
HyperWare Plotter: Built-in plotter within the HyperWare software program. Provides graphical plotting of up to 7 channels,
with full zoom, and x and y-axis control. Minimum, maximum, averages and integral view instantly available.
HyperTrackä: The real-time display environment
of HyperWare. Provides real-time
scrolling of actual data or plotting of data on a connected PC.
HyperWareä: The graphic software environment
developed by Logic Beach to work with Logic Beach data logging and
alarming systems. Provides
an easy-to-use icon-based programming environment for communications,
programming, real-time trending and data post-processing. File conversion to text and Excel utility also included. Runs
under all current Windows operation systems.
Hysteresis: The difference in output when
the measurand value is first approached with increasing and then with
decreasing values. Expressed in percent of full scale during any one
calibration cycle. See also Deadband.
Icon: A graphic functional symbol
display used in HyperWare for communications, programming, real-time
viewing and more. A graphic representation of a function or functions
to be performed by the computer.
Impedance: The total opposition to electrical
flow (resistive plus reactive).
Infrared: An area in the electromagnetic
spectrum extending beyond red light from 760 nanometers to 1000 microns
(106 nm). It is the form of radiation used for making non-contact
temperature measurements.
Input Impedance: The resistance measured across
the excitation terminals of a transducer.
Intrinsically Safe: An instrument which will not
produce any spark or thermal effects under normal or abnormal conditions
that will ignite a specified gas mixture.
Junction: The point in a thermocouple
where the two dissimilar metals are joined.
K: When referring to memory capacity,
two to the tenth power (1024 in decimal notation).
Kilowatt (kw): Equivalent to 1000 watts.
Kilowatt Hour (kwh): 1000 watthours. Kilovolt amperes
(kva): 1000 volt amps.
KVA: Kilovolt amperes (1000-volt
amps).
Large Scale Integration (LSI): The combining of about 1,000 to 10,000 circuits on a single chip.
Typical examples of LSI circuits are memory chips and microprocessor.
Life Cycle: The minimum number of pressure
cycles the transducer can endure and still remain within a specified
tolerance.
Linearity: The closeness of a calibration
curve to a specified straight line. Linearity is expressed as the
maximum deviation of any calibration point on a specified straight
line during any one calibration cycle.
Load Impedance: The impedance presented to
the output terminals of a transducer by the associated external circuitry.
Load: The electrical demand of a
process expressed as power (watts), current (amps) or resistance (ohms).
Loop Powered Sensor: Sensor which acquires it power
from a series DC power source and produces a 4-20mA output proportional
to the rated scale of the sensor.
Loop Resistance: The total resistance of a thermocouple circuit caused by the resistance
of the thermocouple wire. Usually used in reference to analog pyrometers
which have typical loop resistance requirements of 10 ohms.
LS-TTL Compatible: For digital input circuits,
a logic 1 is obtained for inputs of 2.0 to 5.5 V which can source
20 µA, and a logic 0 is obtained for inputs of 0 to 0.8 V which can
sink 400 µA. For digital output signals, a logic 1 is represented
by 2.4 to 5.5 V with a current source capability of at least 400 µA;
and a logic 0 is represented by 0 to 0.6 V with a current sink capability
of at least 16 MA. "LS" stands for low-power Schottky.
M: Mega; one million. When referring
to memory capacity, two to the twentieth power (1,048,576 in decimal
notation).
Mass Flow Rate: Volumetric flowrate times density,
i.e. pounds per hour or kilograms per minute.
Mass Storage: A device like a disk or magtape
that can store large amounts of data readily accessible to the central
processing unit.
Maximum Operating Temperature: The maximum temperature at which an instrument or sensor can be safely
operated.
Maximum Power Rating: The maximum power in watts
that a device can safely handle.
Measuring Junction: The thermocouple junction referred
to as the hot junction that is used to measure an unknown temperature.
Microamp: One millionth of an ampere,
10-6 amps, µA.
Micron: One millionth of a meter, 10-6
meters.
Microvolt: One millionth of a volt, 10-6
volts.
Mil: One thousandth of an inch (.001").
Milliamp: One thousandth of an amp, 10-3
amps, symbol mA.
Millimeter: One thousandth of a meter,
symbol mm.
Millivolt: Unit of electromotive force.
It is the difference in potential required to make a current of 1
millampere flow through a resistance of 1 ohm; one thousandth of a
volt, symbol mV.
Modem: Modulator/Demodulator. A device
that transforms digital signals into audio tones for transmission
over telephone lines, and does the reverse for reception.
ModuLogger: A modular data logging system from Logic Beach in which
additional expansion modules may be added in the field to increase
channel count, functionality or power source.
Mueller Bridge: A high-accuracy bridge configuration
used to measure three-wire RTD thermometers.
Multiplex: A technique which allows different
input (or output) signals to use the same lines at different times,
controlled by an external signal. Multiplexing is used to save on
wiring and I/O ports.
N/C (No Connection): A connector point for which
there is no internal connection.
Negative Temperature Coefficient: A decrease in resistance with an increase in temperature.
NEMA-4: A standard from the National
Electrical Manufacturers Association, which defines enclosures intended
for indoor or outdoor use primarily to provide a degree of protection
against windblown dust and rain, splashing water, and hose-directed
water.
NEMA-7: A standard from the National
Electrical Manufacturers Association, which defines explosion-proof
enclosures for use in locations classified as Class I, Groups A, B,
C or D, as specified in the National Electrical Code.
NEMA-12: A standard from the National
Electrical Manufacturers Association, which defines enclosures with
protection against dirt, dust, splashes by non-corrosive liquids,
and salt spray.
Network: A group of computers that are
connected to each other by communications lines to share information
and resources.
NMR (Normal-Mode Rejection): The ability of a panel meter
to filter out noise superimposed on the signal and applied across
the SIG HI to SIG LO input terminals. Normally expressed in dB at
50/60 Hz.
Normal-mode Rejection Ratio: The ability of an instrument
to reject interference usually of line frequency (50-60 Hz) across
its input terminals.
Offset: The difference in temperature
between the set point and the actual process temperature. Also, referred
to as droop.
Operational pH: The determination of sample
pH by relating to pH measurements in a primary standard solution.
This relationship assumes that electrode errors such as sensitivity
and changes in asymmetry potential can be disregarded or compensated
for, provided the liquid junction potential remains constant between
standard and sample.
Optical Isolation: Two networks which are connected
only through an LED transmitter and photoelectric receiver with no
electrical continuity between the two networks.
Output Impedance: The resistance as measured
on the output terminals of a pressure transducer.
Parallel Transmission: Sending all data bits simultaneously.
Commonly used for communications between computers and printer devices.
pH Junctions: The Junction of a reference
electrode or combination electrode is a permeable membrane through
which the fill solution escapes (called the liquid junction).
Platinum 6% Rhodium: The platinum-rhodium alloy
used as the negative wire in conjunction with platinum-30% rhodium
to form a Type B thermocouple.
Platinum 10% Rhodium: The platinum-rhodium alloy
used as the positive wire in conjunction with pure platinum to form
a Type S thermocouple.
Platinum 13% Rhodium: The platinum-rhodium alloy
used as the positive wire in conjunction with pure platinum to form
a Type R thermocouple.
Platinum 30% Rhodium: The platinum-rhodium alloy
used as the positive wire in conjunction with platinum 6% rhodium
to form a Type B thermocouple.
Platinum 67: To develop thermal emf tables
for thermocouples, the National Bureau of Standards paired each thermocouple
alloy against a pure platinum wire (designated Platinum 2 prior to
1973, and currently Platinum 67). The thermal emf's of any alloy combination
can be determined by summing the "vs. Pt-67" emf's of the
alloys, i.e., the emf table for a Type K thermocouple is derived from
the Chromel vs. Pt-67 and the Alumel vs. Pt-67 values.
Platinum: A noble metal which in its
pure form is the negative wire of Type R and Type S thermocouples.
Polarity: In electricity, the quality
of having two oppositely charged poles, one positive one negative.
Positive Temperature Coefficient: An increase in resistance due
to an increase in temperature.
Potentiometer: 1. A variable resistor often
used to control a circuit. 2. A balancing bridge used to measure voltage.
PPM: Abbreviation for "parts
per million," sometimes used to express temperature coefficients.
For instance, 100 ppm is identical to 0.01%.
Proof Pressure: The specified pressure which
may be applied to the sensing element of a transducer without causing
a permanent change in the output characteristics.
Protocol: A formal definition that describes
how data is to be exchanged.
PSIA: Pounds per square inch absolute.
Pressure referenced to a vacuum.